ARION PDU

STANDARD PDU
WITH UNIVERSAL TYPE OUTLET

Add power points where you need them. Vertically or 19" mounted versions available with 12 or 24 outlets. There are three types of AC plug for 16A and 32A series as shown below.

Disclaimer. All product information and catalogs sheets are updates from time to time and actual product may vary from what is shown.

  • FEATURES
  • STANDARDS & MATERIALS
  • DOWNLOAD
  • Direct vertical mount to Arion rack 42U
  • Universal outlet type accepts with most equipment plugs
  • Available in 220 VAC 16A and 32A
  • LED to monitor the power status
  • High quality 16A and 32A plug
  • Maximum 10 ampere current rating per outlet
  • Single phase
  • Finger guard to prevent accidental switch off of breaker
  • 19” mount versions available

Materials/Finish:

  • Extruded Aluminum Case
  • Tough powder coat finish
  • Standard color is low gloss black.
  • RoHS compliance
  • Conforms to ASTM D610-01 and ASTM B117 (500 hours salt spray test)

ARION MODARION PDU

INTELLIGENT POWER DISTRIBUTION MONITORED PDU

Cheval's new PDU line of power distribution units provides PDU level monitoring with on board "intelligent" option for remote monitoring and control.

Disclaimer. All product information and catalogs sheets are updates from time to time and actual product may vary from what is shown.

  • FEATURES
  • STANDARDS & MATERIALS
  • DOWNLOAD
  • Four banks of 6 IEC 60320F C13 outlets
  • Hot Swap multi function LCD display shows real time Voltage, Current and Frequency.
  • Readout can flip 180 deg. for easy viewing.
  • High precision hydraulic magnetic circuit breaker.
  • Two current transformers improve power management.
  • On board "intelligent" options only require connection to Arion PDU Server (sold separately).
  • Anti trip guard
  • Installs directly to Arion racks
  • Single phase : 220 VAC 32 Amp
  • Display AC voltage : 100-240 volts
  • Display AC current : 0-32 Amperes
  • Maximum 10 ampere current rating per individual outlet.
  • Maximum 15 ampere current rating per bank of 6 outlets
  • RoHS compliant
  • Low gloss dark gray powder coat finish

 

Expansion/Options:

The Arion PDU contains built in communication support via an RJ45 jack to our Arion PDU Server. The server transforms the PDU into an intelligent PDU supporting these critical functions:

  • Remote monitoring and output control
  • Temperature & humidity sensor
  • Event alerts through SMS and Email
  • SNMP support
  • User configurable alarm settings

ARION PDU

INTELLIGENT POWER
DISTRIBUTION MONITORED PDU MULTI-OUTLET SERIES

Add power points where you need them. Vertically or 19” mounted versions available with 12 or 24 outlets. There are three types of AC plug for 16A and 32A series as shown below.

Disclaimer. All product information and catalogs sheets are updates from time to time and actual product may vary from what is shown.

  • FEATURES
  • STANDARDS & MATERIALS
  • DOWNLOAD
  • Four banks of 6 IEC 60320F C13 outlets
  • Four x IEC 60320F C19 outlets
  • 10 x “Universal” outlets
  • Hot Swap multi function LCD display shows real time Voltage, Current and Frequency.
  • Readout can flip 180 deg. for easy viewing
  • Two 16A hydraulic magnetic circuit breaker for each Line 1 and Line 2.
  • Two current transformers improve power management
  • On board “intelligent” options only require connection to Arion PDU Server (sold separately)
  • Anti trip guard
  • Zero U mounts directly to Arion racks

 

Specifications:

  • Single phase : 220 VAC 32 Amp
  • Display AC voltage : 100-240 volts
  • Display AC current : 0-32 Amperes
  • Display line frequency : 47-60Hz.
  • Maximum 10 ampere current rating per individual C13 outlet
  • Maximum 15 ampere current rating per bank of 6 C13 outlets
  • Maximum 13 ampere current rating per individual Universal outlets
  • Maximum 20 ampere current rating per individual C19 outlets
  • RoHS compliant

Expansion/Options:

The Arion PDU contains built in communication support via an RJ45 jack to our Arion PDU Server. The server transforms the PDU into an intelligent PDU supporting these critical functions:

  • Remote monitoring and output control
  • Temperature & humidity sensor
  • Event alerts through SMS and Email
  • SNMP support
  • User configurable alarm settings

Please see our Arion PDU Server product information for full details.

 

ARION PDU

INTELLIGENT POWER DISTRIBUTION
MONITORED PDU : UNIVERSAL MULTIOUTLET SERIES

Cheval's new line of power distribution units provides PDU level monitoring with on board “intelligent” option for remote monitoring and control.

Disclaimer. All product information and catalogs sheets are updates from time to time and actual product may vary from what is shown.

  • FEATURES
  • STANDARDS & MATERIALS
  • DOWNLOAD
  • 24 x Universal Outlets
  • 13 ampere current rating per individual outlet
  • Extruded aluminum housing unit
  • Hot Swap multi function LCD display shows real time Voltage, Current and Frequency.
  • Readout can flip 180 deg. for easy viewing.
  • 32A circuit breaker.
  • Two current transformers improve power management.
  • On board “intelligent” options only require connection to Arion PDU Server (sold separately).
  • Anti trip guard
  • Zero U mounts directly to Arion racks

 

Specification:

  • Single phase : 220 VAC 32 Amp
  • Display AC voltage : 240 volts
  • Display AC current : 0-32 Amperes
  • Display line frequency : 47-60Hz.
  • Maximum 13 ampere current rating per individual outlet.
  • Maximum 32A ampere current rating for total outlet.
  • RoHS compliant
  • High quality scratch resistant powder coat finish

Expansion/Options:

The Arion PDU contains built in communication support via an RJ45 jack to our Arion PDU Server. The server transforms the PDU into an intelligent PDU supporting these critical functions:

  • Remote monitoring and output control
  • Temperature & humidity sensor
  • Event alerts through SMS and Email
  • SNMP support
  • User configurable alarm settings

Please see our Arion PDU Server product information for full details.

ARION PDU

server

Arion PDU Server will enable the Intelligent features of our Arion PDU series to be fully utilized. Expand the functionality of your Arion Monitored PDU to an intelligent PDU able to monitor and control multiple devices.

Disclaimer. All product information and catalogs sheets are updates from time to time and actual product may vary from what is shown.

  • FEATURES
  • STANDARDS & MATERIALS
  • DOWNLOAD
  • Four banks of 6 IEC 60320F C13 outlets
  • Hot Swap multi function LCD display shows real time Voltage, Current and Frequency.
  • Readout can flip 180 deg. for easy viewing.
  • High precision hydraulic magnetic circuit breaker.
  • Two current transformers improve power management.
  • On board "intelligent" options only require connection to Arion PDU Server (sold separately).
  • Anti trip guard
  • Installs directly to Arion racks

 

  • Single phase : 220 VAC 32 Amp
  • Display AC voltage : 100-240 volts
  • Display AC current : 0-32 Amperes
  • Maximum 10 ampere current rating per individual outlet.
  • Maximum 15 ampere current rating per bank of 6 outlets
  • RoHS compliant
  • Low gloss dark gray powder coat finish

Expansion/Options:

The Arion PDU contains built in communication support via an RJ45 jack to our Arion PDU Server. The server transforms the PDU into an intelligent PDU supporting these critical functions:

  • Remote monitoring and output control
  • Temperature & humidity sensor
  • Event alerts through SMS and Email
  • SNMP support
  • User configurable alarm settings

ARION PDU

SENSOR EXPANSION MODULE

The Arion PDU server comes with one on board port for a temperature and humidity sensor. With our optional Sensor Expansion Module (SEM), you can add 6 more sensor ports. Temperature probes come with 1.8 meters of cable and connects to the SEM.

Disclaimer. All product information and catalogs sheets are updates from time to time and actual product may vary from what is shown.

  • FEATURES
  • STANDARDS & MATERIALS
  • DOWNLOAD

Simply plug the SEM to the PDU serverand use the pre-installed software to set up and monitor the devices. The SEM contains one on board temperature & humidity and can connect external 6 temperature probes for a total 7 temperature and 1 humidity probes. An LCD readout with selector button allows for local monitoring.

Installation

  • Insert two M6 caged nuts (balloon 3) into square hole on rear flange of 19” rail at desired location.
  • Fix SEM sensor box with two plastic washer and philips head screw M6x16.
  • Tighten M6 screw with torque 25-30 inch lbs.
  • Connect RJ11 link cable from sensor expansion module to sensor port on PDU server
  • Connect RJ9 from temperature sensor probe into input port